What is the reason why the flow value of the FLECK3200NT controller is not reduced?

What is the cause of the FLECK3200NT controller flow value? There are several reasons for this type of problem:
1. Determine whether the flowmeter line is good. At this time, you can watch whether the small red dot in the upper right corner of the controller is on. If the light is on, the flowmeter line is intact.
2. Check if the outlet valve of the softened water equipment has been opened;
3. After the above 2 points are removed, check whether the time cover on the flow meter is rotating normally.
Therefore, when there is any failure in the FLECK series of softened water equipment, as long as you understand the operating principle and related technical requirements of the supporting equipment, all the problems will become a trivial matter! Fulfill FLECK control valve fault repair parts replacement, look for Yusite water treatment company.
The operating principle of FLECK series softened water equipment:
YS series automatic softening water equipment is based on American PENTAIR softening water treatment technology, and introduces its advanced Fleck FLECK automatic control system, and integrates domestic excellent design and technology to develop internationally advanced softened water treatment equipment. The FLECK control system technology of the United States is simple in shape, easy to operate and reliable in operation, making it an international linger in softening water treatment; all of them can be controlled by microcomputer to make operation easier and management easier. The YS series Fleck water softener uses sodium ion exchange resin to replace the calcium and magnesium ions in the raw water, and becomes a softened water with very low hardness after flowing out of the Fleck softener. When the resin adsorbs a certain amount of calcium and magnesium ions, it must be regenerated. The water softener is replaced with saturated brine soaking resin to replace the calcium and magnesium ions in the resin, and the softening exchange ability of the resin is restored, and the waste liquid is discharged.
Softwater equipment related parameters:
1) Working power supply: 220V/50Hz
2) Inlet water pressure: 0.18-0.6Mpa
3) Working temperature: 0-45 ° C
4) Source water hardness: ≤ 8mmol / L
5) Operation mode: automatic (control can be made manually)
6) Water hardness: ≤0.03mmol/L
7) Regenerant: NaCL
8) Regeneration method: downstream/countercurrent
9) Exchange agent: 001*7 strong acid ion exchange resin
10) Control mode: time / flow