Optical Mini Head Dental Turbine Handpiece LED for Children

Model NO.: WM-029A
Application: Adult, Child
Loading Way: Gland Type
Head Diameter: Small Head
Exhaust Way: Internal Exhaust
Number of Holes: Four Holes
Connection: Without Quick Connector
Rotating Speed: High-Speed Handpiece
OEM: Yes
Chuck Type: Push
Spray: Single Way Spray
Air Pressure: 206~231 Kpa (2.1~2.35 Kgf/Cm2)
Water Pressure: 198kpa (2 Kg)
Speed: 370, 000-420, 000 Rpm
Burs Applicable: φ1.59mm~φ1.6mm
Noise: <70dB
Trademark: Vimel
Transport Package: Standard Export Carton
Specification: 10pcs/box
Origin: China
HS Code: 90184990
Optical mini head handpiece for children

Technicals: 
Type 2 hole / 4 hole
Model Mini head
Spray Single way spray
Chuck type push type
Air pressure at
the back end of HP
206~231 kpa (2.1~2.35 kgf/cm2)
Air pressure at the gauge in the dental unit 240-294 kpa (2.45-3.0 kgf/cm2) 
Water pressure 198kpa (2 kg)  
Speed   370,000-420,000 rpm
Burs applicable φ1.59mm~φ1.6mm
Noise ≤70dB

More details, please contact us.
Kathy
 +86 18575748275


Optical Mini Head Dental Turbine Handpiece LED for Children

Optical Mini Head Dental Turbine Handpiece LED for Children
Optical Mini Head Dental Turbine Handpiece LED for Children
Optical Mini Head Dental Turbine Handpiece LED for Children
Optical Mini Head Dental Turbine Handpiece LED for Children


 How To Clean A Dental Handpiece Prior To Sterilization 
There are two methods of cleaning dental handpieces. One is to use an automatic handpiece system, such as the QUATTROcare Plus, prior to sterilization. The other option is to manually maintain your handpieces. If you elect to manually maintain your handpieces, here are the steps to do so. 
 
Step 1: Clean Handpiece
The first step in cleaning a dental handpiece is to lightly wash the handpiece under cool running water to remove excess debris.
 
Step 2: Handpiece Lubrication
Following external cleaning, connect the handpiece to the handpiece lubricant spray using the appropriate nozzle for the handpiece you are cleaning. For this air handpiece, we are using a multiflex nozzle.  Spray for approximately 2 seconds. We recommend using a cloth or paper towel wrapped around the handpiece to contain the spray. It is ok if some excess lubrication remains in the handpiece.
 
Step 3: Purge Handpiece
After lubrication, you'll want to purge your handpiece. Simply connect the handpiece to your multiflex connection, step on the foot petal and purge for 30-40 seconds. The handpiece is now ready for sterilization.

 