Electronic platform scale display failure emergency plan

Although the outer shell of the electronic platform is made of hard materials, the interior of the electronic platform is basically all electronic components. If the electronic components work in a harsh environment for a long time, some minor problems will inevitably occur. There is a problem with the display of the electronic platform.
Obviously, there is a problem with the electronic platform display, and we will immediately think of the display. But because there are so many components related to the display, we don't know what to do. In fact, when encountering the problem that the display of the electronic platform is not normal or even if there is no display after the boot, we need to do not worry, but analyze the possibility of product error and find out where the error occurred according to the actual situation. The following are some of the emergency treatment methods for the electronic platform scale display:
(1) When the electronic weighbridge is turned on, the display shows the number and jumps irregularly.
Solution: For this kind of problem, consider that the water vapor in the junction box is too heavy and should be blown dry with a hair dryer.
(2) The weighing result is light or heavy after normal power on. Solution: Recalibrate the electronic platform according to the instruction manual. If the problem remains unresolved after calibration, you should consider that the sensor has been damaged.
(3) After the weighing is completed, the weight is removed and the display does not return to zero.
Solution: The above situation should be caused by line breakage and signal attenuation. Check the electronic platform data line for damage. If it should be replaced in time.
(4) The number displayed on the display is unstable when weighing.
Solution: Check if the weighbridge is level and reposition it.
(5) After the power is turned on, the electronic scale display does not respond.
Solution: Check carefully whether the power cable is intact, whether the monitor cable is intact, and replace it if it is damaged.

All of the above are some emergency methods for the weighbridge . If you have mastered the above methods, I believe that your platform will no longer be in trouble.

Molecular Diagnostic POCT

Point Of Care Testing POCT

GENEDIAN iRapid 4 POC RT-PCR Detection System is a fully automatic integrated system with simplified operation, easy to achieve "rapid read results", fully enclosed detection, safe and pollution-free features. Configured with GENEDIAN POC SARS-CoV-2 Nucleic Acid Detection Kit, the 4-well system is able to run independently as well as run four different parameters at the same time.